Controlled-products-systems-group L3NX Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnost Controlled-products-systems-group L3NX. Controlled Products Systems Group L3NX User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - INSTALLATION

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATIONFOR THE VIKING L-3 GATE OPERATORCLASS I, CLASS II, CLASS III, AND CLASS IV Residential and

Strany 2

VIKING TECHNICAL SUPPORT 1.800.908.08848IMPORTANT SAFETY INFORMATIONMAINTENANCERemove the Power Harness from the Control Board (refer to page 18)•Cle

Strany 3

VIKING TECHNICAL SUPPORT 1.800.908.08849a. Use only the following type and size battery(ies): Yuasa NP7-12b. Donotdisposeofthebattery(ies)inre

Strany 4 - PARTS DIAGRAM:

VIKING TECHNICAL SUPPORT 1.800.908.088410IMPORTANT SAFETY INFORMATIONNOTE: This type on installation DOES NOT reverse the gate all the way back to its

Strany 5 - OPERATOR REFERENCES:

VIKING TECHNICAL SUPPORT 1.800.908.088411NOTE: This type on installation DOES NOT reverse the gate all the way back to its limits when the edge sensor

Strany 6 - CONTROL BOARD REFERENCES:

VIKING TECHNICAL SUPPORT 1.800.908.088412Audible Alarm Reset Switch InstallationManual Reset for the Audible Alarm•UL325 standard requires an audible

Strany 7 - TABLE OF CONTENTS:

VIKING TECHNICAL SUPPORT 1.800.908.088413! CAUTION: To Reduce the Risk of Fire or Injury to Persons:! WARNING: For use with gates at a maximum 1600 lb

Strany 8

VIKING TECHNICAL SUPPORT 1.800.908.088414GATE OPERATOR INSTALLATION Concrete Pad Option1. Follow the local building code to determine the required dep

Strany 9

VIKING TECHNICAL SUPPORT 1.800.908.088415Post Mounting OptionTIP: The operator is equipped for post mount applications and is ready for installation.

Strany 10 - IMPORTANT SAFETY INFORMATION

VIKING TECHNICAL SUPPORT 1.800.908.088416Operator Positioning! IMPORTANT: All openings of a horizontal slide gate are guarded or screened from the bot

Strany 11

VIKING TECHNICAL SUPPORT 1.800.908.088417GATE OPERATOR INSTALLATION! TECHNICAL TIP: Before starting the installation procedure;•Openandclosethega

Strany 12

The L-3™ gate operator has the capacity to operate slide gates up to 1600 lbs. and 60 ft. in length at 100% duty cycle under extreme conditions. This

Strany 13

VIKING TECHNICAL SUPPORT 1.800.908.088418High Voltage Supply Option! Caution: Always turn off power breakers when working with high voltage. DO NOT co

Strany 14

VIKING TECHNICAL SUPPORT 1.800.908.088419ALow Voltage Supply OptionTIP: The operator is equipped with a Modular Power Box that can be relocated to pro

Strany 15 - 1600 lb

VIKING TECHNICAL SUPPORT 1.800.908.088420LIMITS SETUPTip: The gate can be moved electronically with the “Open”, “Stop” and “Close” buttons on the Cont

Strany 16 - GATE OPERATOR INSTALLATION

VIKING TECHNICAL SUPPORT 1.800.908.088421LIMITS SETUPTo Readjust the Open Limit:1. Clear the current limit setting by holding down the “Open Limit” bu

Strany 17

VIKING TECHNICAL SUPPORT 1.800.908.088422Two Wire Communication! IMPORTANT: DO NOT run the Master/Slave communication cable in the same conduit or wit

Strany 18

VIKING TECHNICAL SUPPORT 1.800.908.088423MASTER/SLAVE SETUPREQUIRED ADD-ON: Choose option A or BA. Viking Konnect - Wireless Master/Slave Kit PART# VA

Strany 19

VIKING TECHNICAL SUPPORT 1.800.908.088424Initial SettingsCONTROL BOARD SETUP“Timer”Hold Open TimerAutomatically closes the gate after the selected amo

Strany 20 - ELECTRICAL INSTALLATION

VIKING TECHNICAL SUPPORT 1.800.908.088425Initial SettingsNOTE: Installing a shunt or jumper on the pins will activate the feature.CONTROL BOARD SETUP“

Strany 21

VIKING TECHNICAL SUPPORT 1.800.908.088426Obstruction Sensor (Primary Entrapment Protection)! IMPORTANT: The appropriate “ODS” setting is dependant upo

Strany 22 - LIMITS SETUP

VIKING TECHNICAL SUPPORT 1.800.908.088427CONTROL BOARD SETUPHEATERCLS ONLOCK MODONViking HeaterThe operator has an integrated heater that is thermos

Strany 23

L-3 Vehicular Gate Operator • Revision L3NXMN10.D • August 2013

Strany 24 - MASTER/SLAVE SETUP

VIKING TECHNICAL SUPPORT 1.800.908.088428(THIS PAGE LEFT BLANK INTENTIONALLY)

Strany 25

VIKING TECHNICAL SUPPORT 1.800.908.088429Re-Open Photo Beam (vehicular Safety)NOTE: This type of photo-beam installation will stop then RE-OPENS the g

Strany 26 - CONTROL BOARD SETUP

VIKING TECHNICAL SUPPORT 1.800.908.088430Radio Receiver (Typical)! IMPORTANT: The Hold Open “Timer” setting (page 24) effects how the gate will respon

Strany 27

VIKING TECHNICAL SUPPORT 1.800.908.088431Anti-Tail Gate, Open Commands & Guard Station! TECHNICAL TIP: For more information regarding accessory co

Strany 28

VIKING TECHNICAL SUPPORT 1.800.908.088432Viking Loop RackTIP: This operator may be equipped with a pre-wired Loop Rack that plug-in type loop detector

Strany 29 - CLS ON

VIKING TECHNICAL SUPPORT 1.800.908.088433Guidelines for Loop InstallationTable C - Recommended Number of TurnsPerimeter (ft.) Number of Turn

Strany 30

VIKING TECHNICAL SUPPORT 1.800.908.088434Magnetic Lock, Lock SolenoidNOTE: Viking Access Systems does not provide external gate lock devices. These it

Strany 31 - ACCESSORY CONNECTIONS

VIKING TECHNICAL SUPPORT 1.800.908.088435Barrier Arm (B-12) Synchronization OptionNOTE: The Control Board provides a convenient solution for applicati

Strany 32

VIKING TECHNICAL SUPPORT 1.800.908.088436LED ReferencesIn addition to the LCD Display, the control board LEDs monitor the various circuits of the cont

Strany 33

VIKING TECHNICAL SUPPORT 1.800.908.088437LED ReferencesUse the table below to identify the corresponding “TS Ref#” and refer to page 38-41 for further

Strany 34

VIKING TECHNICAL SUPPORT 1.800.908.08842PARTS DIAGRAM:Item Description Part No.1 Chassis VNXL3CH2 Chassis Battery Bracket VNXCHBBRK3 Gear Box VNXL3GB4

Strany 35

VIKING TECHNICAL SUPPORT 1.800.908.088438TROUBLESHOOTINGCall out LCD Display, Diag-nose Button and Diag-nose LEDLCD MSG MeaningPage 41 TS Ref #s VIKIN

Strany 36

VIKING TECHNICAL SUPPORT 1.800.908.088439TROUBLESHOOTINGLCD Display ReferencesLCD MSG MeaningPage 41 TS Ref #sMulti Meter DisplaysMOT AMP __._ AThis

Strany 37 - SYNCHRONIZATION WITH B-12

VIKING TECHNICAL SUPPORT 1.800.908.088440TROUBLESHOOTINGLCD Display References LCD MSG MeaningPage 41 TS Ref #sError MessagesERR AC LOWIndicates th

Strany 38 - TROUBLESHOOTING

VIKING TECHNICAL SUPPORT 1.800.908.088441TROUBLESHOOTINGSolutionsBegin the troubleshooting process by referring to the error messages on the LCD Displ

Strany 39

VIKING TECHNICAL SUPPORT 1.800.908.088442Access Control ConnectionsAppendix (A)Power ConnectionsThe control board provides a 24v DC output to power ex

Strany 40 - System Status Messages

VIKING TECHNICAL SUPPORT 1.800.908.088443Relays In GeneralNOTE: Viking Access Systems does not provided the external safety devices and access control

Strany 41 - Board Settings Messages

VIKING TECHNICAL SUPPORT 1.800.908.088444Common Radio Receivers - ConnectionsAppendix (B)

Strany 42 - Error Messages

VIKING TECHNICAL SUPPORT 1.800.908.088445Solar ApplicationsNOTE: Viking recommends Solar Package (part # VA-SOCHP) for most general solar applications

Strany 43

VIKING TECHNICAL SUPPORT 1.800.908.088446VIKING EXPANSION PRODUCTSVIKING SOLAR KIT The components included in this package are intended to provide suf

Strany 44 - Appendix (A)

Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and it’s needs. As

Strany 45 - APPENDIX (A)

VIKING TECHNICAL SUPPORT 1.800.908.08843OPERATOR REFERENCES:1. OPERATOR COVER 2. COVER LOCK3. ACCESS DOOR external access to the Manual Rele

Strany 46 - Appendix (B)

VIKING ACCESS SYSTEMS631 Wald Irvine, CA 92618Phone 800.908.0884Fax 949.753.1640www.vikingaccess.comSTANDARD FEATURESAND OPERATOR SPECIFICATIONS• UL32

Strany 47 - APPENDIX (C)

VIKING TECHNICAL SUPPORT 1.800.908.08844CONTROL BOARD REFERENCES:1. POWER HARNESS CONNECTOR provides power to the control board. pg 18-192. “OPEN LE

Strany 48 - VIKING EXPANSION PRODUCTS

VIKING TECHNICAL SUPPORT 1.800.908.08845TABLE OF CONTENTS:PARTS DIAGRAM/PARTS LIST 2OPERATOR REFERENCES 3CONTROL B

Strany 49

VIKING TECHNICAL SUPPORT 1.800.908.08846IMPORTANT SAFETY INFORMATIONIMPORTANT SAFETY INSTRUCTIONS! WARNING! To reduce the risk of severe injury or dea

Strany 50 - STANDARD FEATURES

VIKING TECHNICAL SUPPORT 1.800.908.08847IMPORTANT SAFETY INFORMATIONIMPORTANT INSTALLATION INSTRUCTIONS (Continued)6. Controls intended for user activ

Komentáře k této Příručce

Žádné komentáře